TrigasDM Turbine Flowmeters are the perfect choice for liquid measurement applications that call for high precision, lightning-quick response times, and compact design. They offer exceptional dependability in continuous operation, constant flow variations, and fluctuating operating temperatures. TrigasDM Flowmeters are not susceptible to shock, dampness, or vibration. Additionally, customized IP67 versions with receivers and electrical amplifiers are available.
TrigasDM The use of turbine flow meters is very widespread. For instance, monitoring the flow rates of fuels and coolants in engines and engine development, measuring and monitoring ultrapure water in research and development, and administering precise amounts in the food and pharmaceutical industries.
Technical Properties:
- Linear Flow Range: 7,6 l/min to 90 l/min (2 GPM to 23.8 GPM)
- Extended Flow Range: 0,9 l/min to 95 l/min (0.24 GPM to 25.1 GPM)
- Operating Pressure: up to 410 bar
- Pressure Loss (at 70% linear flow): 0,64 bar
- Temperature Range: -270°C to 400°C (-454°F to 752°F)
- Response Time: <3 ms
- Calibration Accuracy: ≤±0,03% of measurement
- Repeatability: ≤±0,05% of measurement
- Linearity in Linear Flow Range: ≤±0,5% of measurement
- Linearity with Linearizer: ≤±0,1% of measurement
- K-Factor: 1260 Impulse/l
- Max. Frequency: 2000 Hz
- Housing and Turbine Material: Stainless Steel
- Ball Bearing Material: Ceramic bearings, Steel cage
- Weight: 133 g
- Inner Diameter: 14,3 mm
- Length: 82,5 mm
- Connection: HS-L hose connection
- Connection size: 0,75″
- Recommended Prefiltration: 10µ
- Recommended Inlet: 143 mm
- Recommended Outlet: 72 mm
- Standard- viscosity:: 1,3 mm²/s