THM06 Industrial Temperature and Humidity Transmitter

Temperature and Humidity Transmitter For Industrial Use

THM06 has a robust exterior housing and a variety of uses. It can be used in tough environmental conditions as well.
Capacitive sensors feature quick response times, good measurement accuracy for temperature and humidity, and quick recovery from condensation.
It is appropriate for industrial process gas supply or consumption, compressed dry air flow, and consumption monitoring. It is stable even in long-term high humidity. It also offers temperature compensation and a computer-linear calibration of temperature and humidity.

Adaptation to difficult surroundings such chemical pollution and condensation or high temperatures and high humidity conditions.

  • IP67, Stainless steel SUS304, Pressure resistance 16 bar
  • 330° rotatable, lightweight, unrestricted installation
  • Optional on-site real-time display
  • Process temperature up to 180°C, custom up to 200°C (Optional)
  • Output : Analog / RS-485
  • Wide measurement range, Temp. : -40 ... +180°C, Humidity : 0 ... 100%RH
  • Measuring parameter : relative humidity, dew point temperature, frost point temperature, wet bulb temperature, water vapor partial pressure, mixing ratio, absolute humidity and enthalpy.

Application:

Semiconductors, electronics, steel, chemicals, pharmaceuticals, biotechnology, tobacco, controlled environments, high humidity storage, and food are among the industries that use industrial process control (drying or humidification).

Technical Properties:

  • Signal type : Capacitive humidity sensor & Pt100
  • Temperature range : -40°C ... +180°C, Customized up to 200°C (Optional)
  • Humidity range : 0 ... 100%RH (non-condensing)
    (Please refer tophysical quantity measuring range list)Signal : 4 ... 20 mA / 0 ... 10 V / RS-485
  • Signal connection : 3-wire
  • Temperature : ±0.15°C+0.002°C x tactual
  • Humidity (0 ... 90%) : Nonlinear error:±1.2%RH, Hysteresis error:±0.8%RH, Repeatability error:±0.4%RH
  • Humidity (90 ... 100%) : ±2%RH
  • Reaction time t90 (at +25°C) : <20 sec (S.S. metal grid filter with mesh), <30 sec (Sintered filter)
  • Load resistance : Current output:≦ 500 Ω, Voltage output:≧ 100 KΩPower supply : DC 24 V±10%
  • Current consumption : DC 24 V:60 mA
  • Electrical connections : M12 connectorMedium : Air, or medium compatible with stainless steel
  • Temp. Operating : -20 ... +60°C (Body);-40 ... +180°C (Probe)
  • Humid. Operating : 0 ... 90%RH (Body, non-condensing)
  • Probe pressure : 16 bar
  • Storage temperature : -20 ... +60°CInstallation : 1/2" PT movable thread
  • IP rating : IP67
  • Electrical protection : ■Reverse polarity ■Over-voltage ■Short-circuit
  • Housing : SUS304
  • Weight : Metal:318 g (without wire)

rst-electronics