FTE120-I Inline Type Air Flow Transmitter
Features
- Multiple outputs that are optional include: 4...20 mA, 0...10 V, RS-485, Frequency, and Pulse.
- Precision: 2% F.S. Operating pressure: 10 bar maximum
- Sonic nozzle calibration method used for calibration
- Easy installation and several diameters (DN10, DN15, DN20, and DN25)
- Aluminum alloy pipes and polycarbonate housing
- Programmable RS-485 software Charts and data logger
Applications
- Pneumatic system
- Compressed air system
- Industrial machinery equipment
- Pipeline air flow monitoring
Technical Properties
- Input
- Sensor type: Thermal mass flow sensor
- Measuring range: DN10 : 0 ... 150 l/min
DN15 : 0 ... 500 l/min
DN20 : 0 ... 1000 l/min
DN25 : 0 ... 1500 l/min - Minimum measuring range: 5 l/min
The measurement range is defined at the standard condition(1013 mbar, 20°C). This product is also calibrated at this condition. - Output
- Signal: 4 ... 20 mA / 0 ... 10 V / RS-485 / Frequency ( 0 ... 100 Hz ) / Pulse ( 1 ... 100 l/pulse, option )
- Accuracy: ±2% F.S.
- Temp. influence: 0.2% / °C
- Response time: t90≦5 sec
- Load resistance: Current output : ≦ 500 Ω, Voltage output : ≧ 100 KΩ
- Warm-up time: < 2 min.
- Environmental
- Medium: Air
- Housing operating Temp. / Humid: 0 ... 50°C / 0 ... 95%RH(Non-condensing)
- Medium operating Temp. / Humid: 0 ... 50°C / 0 ... 95%RH(Non-condensing)
- Storage Temp.: -20 ... +60°C
- Operating pressure: 10 bar
- Electrical
- Power supply: DC 24 V ±10%
- Current consumption: 100 mA
- Overvoltage protection: DC : < 40 V
- Electrical connections: PVC cable (1 m)
- Installation
- Inline type: DN10 - G1/4″
DN15 - G1/2″
DN20 - G3/4″
DN25 - G1″
- Protection
- IP rating: IP 65 (Housing) / IP20 (Probe)
- Electrical protection: Reverse polarity, Over-voltage ,Short-circuit
- Certification: CE
- Material
- Housing : PC
- Pipe : Aluminum alloy
- Weight : DN10 : 160 g
DN15 : 400 g
DN20 : 465 g
DN25 : 520 g